Alfa-laval plate heat exchanger installation manual

Each package is handled by our expert service team and is supported by alfa lavals more than 70 years of gphe experience. Alfa laval reconditioning services for gasketed plate heat exchangers are organized into three packages. Applications for your utility heating and cooling duties the industrial plate heat exchangers of alfa laval can be used. Identify the causes of various issues you might experience with your plate heat exchanger, or even better how to prevent them from happening, through our online troubleshooter. This means that the plate package is tightened to its correct measurement a. T5 flow principle of a plate heat exchanger plate heat exchanger applications general heating and cooling duties.

Plate heat exchanger calculation method alfa laval. Our robust, efficient and compact designs have a proven reputation for high reliability in some of the toughest process duties across industries. Paraflow instruction manual gasketed plate heat exchangers. Document id language edition 4 instruction manual plate heat exchangers 3490010217 en 201606. Figure 1 shows typical components of a plate heat exchanger. These are detailed in the following product sheets. Alfa laval assembly of gasketed plate heat exchanger for. Swep offers a 12month warranty from the date of installation, but in no case longer than 15 months from the date of delivery. Instruction manual brazed plate heat exchangers en. The animation shows the building components of an industrial gasketed heat exchanger. Safety considerations the semi welded plate heat exchanger shall be used and maintained in accordance with alfa lavals. Troubleshooting your gasketed plate heat exchanger. Always follow the instruction manual and the plate hanging list. The animation shows the components of an industrial heat.

Instruction manual fusion plate heat exchangers alfanova 76. If needed our experienced and skilled troubleshooters. Service kits and spare parts disc stack separators. Manual tightening of the plate pack the plate pack is mounted against the fixed head. Welded heat exchangers alfa laval compabloc condenser alfa laval compabloc plate condensers offer a compact and costefficient alternative to traditional shellandtube or graphite block condensers. Alfa laval m6mfg plate heat exchanger alfa laval m6mfg plate heat exchanger type. The port filter length is precisely adapted to the specific plate heat exchanger. For maintenance actions not described in this manual, contact your alfa laval representative for advice. Plate heat exchanger eng 1 eng description definitions plate heat exchanger assembly of one or more plate packs and its supporting frame. Always consult your local alfa laval representa tive for a.

This instruction manual is your instant guide, when dealing with your alfa laval plate heat. Alfa laval alfaq gasketed plate andframe heat exchangers are available to meet most heat transfer requirements whether large or small demonstrating our commitment to optimizing the performance of our customers processes. The corrugation on the plates causes high turbulence, which results in substantially higher heat transfer efficiency. Threaded studs around the holes secure the pipes to the equipment. Alfa laval 2pass gasketed plate andframe heat exchanger features that make the difference the industrial line is equipped with features that turn this highperformance family into efficient and reliable workhorses that are easy to service and maintain over the whole product lifecycle. The heat exchanger shall be used and maintained in accordance with alfa lavals instructions in this manual. Ensures plate and gasket materials meet current process media and temperature requirements thereby prolonging the service interval between plate and gasket replacement.

Alfanova 76 industrial equipment pdf manual download. Alfa laval phe manual m15, tl10, tl20, ts20, mx25, m30, ma30. We assure the right parts with the right fit and specifications. The plate heat exchanger consists of a pack of corrugated metal plates. Alfadisc allwelded plate heat exchanger alfa laval.

Fluids normally run countercurrently through the heat exchanger. Our experts have vast experience in installing equipment, so you can rest assured knowing it is installed according to the latest requirements. If you nevertheless should have a problem with your alfa laval plate heat exchanger which is beyond the scope of this manual, do not hesitate to turn to your alfa laval representative. View and download alfa laval t35 instruction manual online. Alfa lavals ts6 gaskets plate andframe heat exchanger is designed to heat water or cip solutions by means of steam. A safe and correct installation of your equipment secures good operation and maintenance throughout its entire lifetime, which saves both time and money. Except for this instruction manual, the following documents are also included in this shipment. Unless otherwise agreed, alfa laval delivers the plate heat exchanger ready to be put in service upon arrival. The features highlighted are the bearing boxes on the tightening bolts. Page 14 english maintenance regasketing glued gaskets open the plate heat exchanger according to page 8, and remove the plate that is to separate gluing instructions will be delivered togeth have a new gasket. The heat transfer takes place through the thin plates in stainless steel, titanium or smo and it is a highly efficient heat exchange technique. Product information is currently available only for gasketed and welded heat exchangers as well as. Incorrect handling of the heat exchanger may result in serious consequences with injuries to persons andor property damage. The warranty covers only manufacturing and material defects.

Instruction manual alfa laval brazed plate heat exchangers. Alfa laval plate heat exchangers frontline, baseline, m. Phe drawings phe plate heat exchanger drawings mentioned in the manual are the drawings included in the delivery of the heat exchanger. M6 alfa laval pdf catalogs technical documentation. How to change plates of a alfa laval plate heat exchanger baseline and frontline type. Page 14 english maintenance regasketing glued gaskets open the plate heat exchanger according to page 8, and remove the plate that is. The alfa laval cb range of copper brazed plate heat exchangers feature efficient heat transfer with an extremely small footprint, making them ideal for demanding installations where space is at a premium. Instruction manual alfa laval industrial line m15 tl10 tl15 t20 ts20 t25 mx25 ma30 widegap 100 lithuanian. Plate heat exchanger 2 operation and maintenance manual. For your information, see chapters 4a or 4b function. Alfa laval alfanova 76 instruction manual pdf download. En semi welded plate heat exchanger 34900062 rev 201407 en preface this manual provides information needed to install, operate and carry out the maintenance of the semi welded plate heat exchanger swhe. In alfa laval plate heat exchangers, heat is transferred from one medium to another through thin metal plates which have been pressed into a special pattern.

Chapters installation and opera tion of this manual are applicable to full extent. Figure on page 2 shows typical components of a fusion plate heat exchanger. Inspection of unit at regular intervals and as frequently as experience indicates, an examination should be made of the interior and the exterior of the heat exchanger. Contherm 6x9, contherm 6x6, contherm max 48, contherm 6x11.

Heat transfer precision improved temperature approach, true countercurrent flow, 80. Incorrect handling of the plate heat exchanger may result in serious consequences with injuries to persons andor property damage. Watch the assembly of the worlds most modern gasketed plate heat exchanger. Alfa laval offers a wide range of chemical products to improve and increase the performance of our equipment, for the following categories. To avoid hand injuries owing to sharp edges, protective gloves should always be worn when handling plates and protective sheets. Installation english installation requirements multipass units.

The plate heat exchanger shall be used and maintained in accordance with alfa lavals instructions in this manual. High efficiency and versatile design make the alfa laval baseline gasketed plate heat exchangers gphes solid choices for a wide range of hygienic heat transfer applications. Alfa laval will not accept responsibility for any damage or injury. Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. M3, m6, m10, m15 series plate heat exchanger alfa laval. Plate heat exchanger reconditioning and repair alfa laval. Pct00115en 0905 how to contact alfa laval uptodate alfa laval contact details for all countries are always available on our website at. Connections holes matching the piping lead through the frame plate, permitting the media to enter into the heat exchanger. How do you calculate the heat transfer area of a plate heat exchanger. Alfa laval brazed heat exchangers 6 part number 3450021401 english protection against thermal orand pressure fatiguesudden temperature and pressure changes could cause fatigue damage to the heat exchanger. Alfa laval phe manual m15, tl10, tl20, ts20, mx25, m30. Easy to install selfcleaning low level of service and maintenance is required all units are pressure and leak tested gasket free width. Alfa laval keeps spare parts stock for many current heat exchangers as well as for older models. Alfa laval is the only supplier on the market with more than a halfcentury of experience with spiral technology.

This manual provides information needed to install, operate and carry out maintenance of your gasketed plate heat exchangers. Inspect the sliding surfaces of the carrying bar and wipe clean. This includes the food, dairy, beverage, home and personal care, biotech and pharmaceutical industries, providing owners and operators with peace of mind. This manual covers the apv paraflow gasketed plate heat exchangers. It also performs general heating and cooling duties. We value you as our customer and wish to assure your satisfaction. Alfa lavals range includes all sizes, ntu and ports ranging from 15 mm to 120 mm different channel plates, asymmetric plates and different pressure range to secure we have a perfect fit for all kind of duties. View and download alfa laval alfanova 76 instruction manual online. The plate pack performing such a service is called a section. Fusion plate heat exchanger a number of corrugated plates and its frame bonded to a plate pack at high temperature. Ten top tips to keep your alfa laval gasketed plate heat exchanger in tip top condition 20161025 81 kb wise investmentgaskets.

Plate heat exchanger eng 9 eng manual cleaning opening drain the plate heat exchanger. Design the brazing material seals and holds the plates together at the contact points ensuring optimal heat transfer. This animation shows the working principle of an alfa laval liquidliquid 2pass gasketed plate and frame heat exchanger where the fluids run countercurren. With added support from a worldwide network of local service experts, you can count on your spiral heat exchanger delivering truly. Connection plate plate used to separate two or more services in one plate heat exchanger. Warranty conditions the warranty conditions are usually included in the signed sales contract prior. Plate heat exchanger operational and maintenance manual. Equipped with welldesigned features the heat exchangers are easy to maintain and have a long service life. Frame plate the media to enter into the heat exchanger. We have prepared this instruction manual to assist you with your alfa laval plate heat. Lubricants, cleaning agents descalants, corrosion inhibitors, ph stabilizers, flocking agents for separation, adhesives, surface enhancers reconditioners. Heat transfer precision improved temperature approach, true countercurrent flow, 8090% less holdup volume. An easytouse tool that provides information and manuals to manage your alfa laval products. Industrial equipment alfa laval t35 instruction manual.

All alfa laval brazed plate heat exchangers can be offered with different connections to make the installation at the customer site easy. Plate heat exchanger operational and maintenance manual 30. If there is any uncertainty about the storage of the heat exchanger, consult an alfa laval representative. Document id language edition 4 instruction manual plate heat exchangers 3490017599 en 201606. In this section, names of heat exchanger parts are mentioned for the first time. Here, you will find comprehensive information on plate heat exchangers, including product information, manuals, applications ideas and application data forms for telling us the details about your needs. Ts35, tl35, t45, ts50, widegap 350, t50, baseline m, base 10, m line 6, base 11, m line 10, m line 15, base 6. Read this manual carefully before unpacking the equipment. Design tips n tricks gasketed plate heat exchanger. Alfa laval ad vises you to study it carefully, and above all to ensure its availability to those who install, maintain and operate the apparatus on a daily basis. Alfa laval t35 instruction manual pdf download manualslib. Installation and maintenance manual plate heat exchanger. The heat transfer area of a gasketed plate heat exchanger consists of a series of corrugated plates, assembled between a frame and pressure plates to retain pressure.

Open the heat exchanger and confirm the plates hang in the same order as per the plate hanging list. When doing a service mark the side of the plate pack with a diagonal line andor number each plate in the correct order they hang in the heat exchanger. Alfa laval will not be responsible for any breakdown of the equipment caused by the owners failure to follow the instructions of this manual. This helps reduce downtime and extend plate service lifetime. Alfa laval 2pass gasketed plateandframe heat exchanger. You can also perform a full reconditioning at your nearest alfa laval service center. Change plates alfa laval heat exchanger baseline frontline. This lets you choose the option that best meets your time, budget and application requirements. The mobile head is then pushed into contact with the plate pack. Innovative features for this single circuit heat exchanger include the patented equalancer systemtm for efficient distribution of the refrigerant throughout the plate pack. Typical applications evaporator and condenser in chillers and heat pumps economizer in chillers and heat pumps the standard design supports a wide variety of hfc. If there is more than one plate pack, connection plates are used to separate them. Assembly of alfa laval gasketed plate heat exchanger youtube.

View and download alfa laval m3 instruction manual online. Alfa laval genuine spare parts ensure that an investment in a gasketed plate heat exchanger continues to pay off. Safety considerations the heat exchanger shall be used and maintained in accordance with alfa lavals instructions in this manual. The cb range is used in hvac heatingcooling, air conditioning, refrigeration, process heatingcooling, oil cooling, solar heating and many. Alfa laval will not accept responsibility for any damage or. This instruction manual is your instant guide, when dealing with your alfa laval plate heat exchanger in various situations. The baseline heat exchanger from alfa laval is the standard range of gasketed plate and frame heat exchangers used in the dairy, food, beverage, and other sanitary processing segments. Plate heat exchangers for refrigeration alfa laval pdf. This manual provides information needed to install, operate and carry out maintenance of your gasketed plateandframe heat exchanger. Gasketed plate heat exchanger spare parts alfa laval. Modifications to the plate heat exchanger may make the port filter not fit the dimensions of the plate heat exchanger anymore. Alfa laval m3 instruction manual pdf download manualslib. Standard design the plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place.

Contherm 6x3 industrial equipment pdf manual download. M6 m6fg plate heat exchanger applications general heating and cooling duties. The heat load of a heat exchanger can be derived from the following two formulas. View and download alfa laval contherm 6x3 instruction manual online. Allwelded plate heat exchanger alfadisc applications alfadisc is suitable for most of the applications, such as general cooling and heating duties, condensation, evaporation, reboiling and stream heating. The animation shows the components of an industrial heat exchanger. Separate publications describe other apv equipment. Standard design the plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will. Quick startup and shutdown is a major cause of heat exchanger damage. Manuals for the hisaka plate heat exchanger consist of the following seven related documents. Connections holes matching the piping lead through the frame plate, permitting 1.

Each plate is moved along the upper guide bar and is pressed against the preceeding plate. En 8 plate heat exchanger en manual cleaning opening drain the plate heat exchanger. If you do not find the parts you are looking for, please start a chat. P heat load btuh m mass flow rate lbh cp specific heat btulb f.

The baseline is a competitive choice for hygienic processes and utility applications and meets all hygienic heating and cooling requirements. With the various type of gasketed plate heat exchanger available, there are advantages and disadvantages of choosing a gasketed plate heat exchanger. Alfa laval brazed plate heat exchanger manual squarespace. Ensures the plate heat exchanger configuration meets current process requirements.

1 1720 846 477 1559 1335 1425 832 1055 241 1836 1834 743 1605 360 1404 552 338 312 411 1706 820 87 1688 270 1768 554 1329 31 1677 1095 1460 1256 814 1205 1135 21 1707